FireSAFE 4X
- 4-Hour Fire-Rated
- 8 ft x 40 ft
- 57 Barrels
- 55 Gal Storage Drums
- 228 Square Feet storage
Compliant storage and rental solutions for Phosphorus Pentasulfide (P₂S₅). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.
Phosphorus Pentasulfide is a greenish-yellow solid with a rotten egg odor. It is used in the production of safety matches, lube oil additives, and pesticides.
Acute oral toxicity Category 4 Acute Inhalation Toxicity - Dusts and Mists Category 4 Combustible dust Yes
Dry Chemical fire suppression is recommended for Phosphorus Pentasulfide
Guidance: Dry Chemical fire suppression is generally recommended for Phosphorus Pentasulfide (P₂S₅). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: Water mist may be used to cool closed containers. CO 2, dry chemical, dry sand, alcohol-resistant foam.
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Phosphorus Pentasulfide should account for its listed hazards (Flammable solids Category 1 Substances/mixtures which, in contact with water, emit flammable gases ), climate control needs (below +30°C.), and segregation requirements. Phosphorus Pentasulfide is not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORIN
Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.
Properties: Odor Stench Odor Threshold No information available pH 1 10 g/L (20°C) Melting Point/Range 286 - 290 °C / 546.8 - 554 °F Boiling Point/Range 514 °C / 957.2 °F @ 760 mmHg Flash Point > 100 °C / > 212 °F Evaporation Rate Not applicable Flammability (solid,gas) No information available Flammability or explosive limits Upper No data available Lower No data available Vapor Pressure 1 mmHg @ 300 °C Vapor Density Not applicable Specific Gravity 2.080 Solubility Insoluble in cold water Partition coefficient; n-octanol/water No data available Autoignition Temperature 282 °C / 539.6 °F
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Phosphorus Pentasulfide in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Flammable solids Category 1 Substances/mixtures which, in contact with water, emit flammable gases). Climate range guidance: below +30°C.. Compatibility notes: Phosphorus Pentasulfide is not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORIN US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Yes — Phosphorus Pentasulfide is flagged as a flammable hazard in this database (Yes). Flash point: > 100 °C / > 212 °F. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.
Phosphorus Pentasulfide is listed as: Flammable solids Category 1 Substances/mixtures which, in contact with water, emit flammable gases. Acute oral toxicity Category 4 Acute Inhalation Toxicity - Dusts and Mists Category 4 Combustible dust Yes
Dry Chemical fire suppression is generally recommended for Phosphorus Pentasulfide (P₂S₅). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Phosphorus Pentasulfide. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.